ASTM D4417 PDF

For hot-dip galvanizing applications, it is possible to measure and verify the steel surface profile according to ASTM D, Standard Test. ASTM D – 11 Standard Test Methods for Field Measurement of Surface Profile of Blast – Download as PDF File .pdf), Text File .txt) or read. ASME B, Surface Texture (Surface Roughness, Waviness and Lay); ASTM D, Standard Test Methods for Measurement of Surface Profile of Blast.

Author: Zujind Faetaxe
Country: Montserrat
Language: English (Spanish)
Genre: Finance
Published (Last): 22 December 2007
Pages: 63
PDF File Size: 5.5 Mb
ePub File Size: 1.87 Mb
ISBN: 651-9-64565-251-4
Downloads: 99863
Price: Free* [*Free Regsitration Required]
Uploader: Kilkis

Authored by Alana Hochstein.

For hot-dip galvanizing applications, it is possible to measure and verify the steel surface profile according to ASTM D, Standard Test Methods for Field Measurement of Surface Profile of Blast Cleaned Steel, aztm to application of repair materials where the surface has been prepared via power tool or abrasive blast cleaning methods. Recent d417 to ASTM D provide updated test methods to reflect the latest advances in technology and newly accepted industry research.

Updates to ASTM D4417

The three asym methods described within D for measuring surface profile include visual comparators, surface profile depth micrometers, and replica tape.

Only the use of surface profile depth micrometers and replica tape were updated, and the specification changes are as follows:. Visual Comparator – This test method, as well as the comparator d44117 available on the market, have stayed the same, and therefore there were no updates for this test method.

  GLEMBAJEVI KNJIGA PDF

Surface Profile Depth Micrometer – It is now required that the maximum individual reading of 10 or more surface profile readings per area are to be reported, rather than taking the average of ten readings per area.

Updates to ASTM D | American Galvanizer’s Association

Larger repair areas or prepared hot-dip galvanized surfaces for painting can be measured with 10 readings taken from a minimum of three, 6×6 inch 15×15 cm areas. The standard does not address discarding outliers, but an update to the standard addressing outlier readings is planned.

These changes reflect industry research on current tooling which revealed averaged measurements are consistently less than the values obtained using replica tape.

Instead, recording of the highest reading when using a depth micrometer most closely matches the same measurements produced using replica tape.

Differences in Surface Profile Measurements: ASTM D4417- Method B vs. Method C

Replica Tape – Although the technology has remained mostly constant for replica tape since its introduction, industry research has addressed the sufficient number of readings required to achieve an accurate measurement.

As a result, only two readings per area are now required to be averaged to obtain one measurement, instead of the three readings aastm required.

  ERIC MARIENTHAL COMPREHENSIVE JAZZ STUDIES PDF

For measurements that fall between tape sizes, it is still required that two readings using each tape are to be averaged to comprise one reading i. Larger repair areas s4417 prepared hot-dip galvanized surfaces for painting can be measured with two readings taken from a minimum of three, 6×6 inch 15×15 cm areas.

Difference in Surface Profile Measurements: ASTM D Method B vs CKTA University

For more information related to surface preparation as it relates to hot-dip galvanized steel, you can contact AGA Corrosion Engineer Alana Hochstein at ahochstein galvanizeit. The material provided herein has been developed to provide accurate and authoritative information about after-fabrication hot-dip galvanized steel.

This material provides general information only and is not intended as a substitute for competent professional examination and verification as to suitability and applicability. The information provided herein is not intended as a representation or warranty on the part of the AGA.

Anyone making use of this information assumes all liability arising from such use. October 18, Authored by Alana Hochstein.

Only the use of surface profile depth micrometers and replica tape were updated, and the specification changes are as follows:

Back to top