informations à fournir par le fabricant. STANDARD. ISO. Second edition . Reference number. ISO (E). Provläsningsexemplar. ISO Implants for Surgery – Active Implantable Medical Devices – Part 1: General Requirements for Safety, Marking and for Information to be Provided. It is most important that the objectives and potential uses of an. AAMI product standard or recommended practice are clearly understood. The objectives of.

Author: Sanos Sale
Country: Mauritius
Language: English (Spanish)
Genre: Business
Published (Last): 16 December 2005
Pages: 320
PDF File Size: 8.55 Mb
ePub File Size: 12.64 Mb
ISBN: 600-2-91636-561-5
Downloads: 56612
Price: Free* [*Free Regsitration Required]
Uploader: Met

Analytical techniques such as scanning electron microscopy SEMinfrared spectroscopy and stress-strain analysis should be used to document the biostability of the insulation material. I can’t find what I’m looking for. It is recommended that testing be carried out according to Section Where claims are made regarding lead polarization, data from bench testing should be provided to support these claims.

Guidance Document – Medical Device Applications for Implantable Cardiac Leads

Under Part 1 of ISO for AIMDs, non-implantable supporting equipment must be evaluated to the specifications to certain electrical standards, including: This standard replaces ISO Insulation integrity and tensile force testing verifies that the leads are capable of withstanding tensile forces occurring after implantation, without fracture of any conductors or joints or breaching of any functional electrical insulation.

Several years of patient follow-up data might be required to assess the biostability of a new lead. Where all possible shock configurations are not assessed, provide a justification as to why no additional testing is required.

For more complex leads with multiple connectors e. The requirements of Parts listed above supplement or modify those of Part 1. The manufacturer should demonstrate that corrosion resistance of conductors and electrode materials meet device specifications.

Lists of National Standards

Gaming the Healthcare System. A requirement for clinical testing could arise for new leads with little or no clinical history or leads with new designs, components, functions, or new indications for use. It is the responsibility of the manufacturer to determine izo tests appropriate for each device and to formulate a comprehensive testing strategy to ensure that safety and effectiveness objectives are met.

  GUIDA NVU ITALIANO PDF

Validation testing should be provided that supports the adoption of device sterilization methods that conform with recognized ISO standards. Appropriate evaluation methods should be used to establish the safety and effectiveness of drug-eluting leads by assessing the role of the drug in improving lead electrical performance.

Although it 14708–1 recognized that distal components may require less tensile strength than proximal components, a five Newton load 5 N is often used as a minimum benchmark for acceptability. Option to visualize changes at a glance. This guidance document applies to applications for an investigational testing authorization, a device licence or a licence amendment and is intended to be used by manufacturers of permanent endocardial transvenous leads with active or 1470-81 fixation mechanisms hereafter referred to as implantable cardiac leads.

Caution the offer 1 user is reserved for a single user, any broadcast even within his company is prohibited. Other useful information in this regard can be obtained in the following:. It is recommended that the manufacturer also verify that the lead passes through its introducer without bond delamination or insulation damage.

Implantable infusion pumps SFDA. Prior to testing, the leads or lead components are preconditioned as fully assembled and shipped product.

Implants for surgery – Active implantable medical devices – Part 2: Devices With Active Fixation Design: A rationale for the test method selected and test acceptance criteria should be provided.

Clinical effectiveness indicators include implantation success, voltage stimulation thresholds, sensing characteristics and pacing impedances.

As a corollary to the above, it is equally important to note that Health Canada reserves the right to request information or material, or define conditions not specifically described in this document, in order to allow the Department to adequately assess the safety, efficacy or quality of a therapeutic product.

The defibrillation threshold in joules [J] and impedance in ohms should be measured if the device is designed for cardioversion or defibrillation. General requirements for safety, marking and for information to be provided by the manufacturer SFDA.

This standard specifies general requirements for AIMDs to provide basic assurance of safety for patients and users. The following validation testing is recommended:.

The implementation date is October 25, AIMDs are complex devices subject to rigorous regulatory standards by authorities across the globe. Cookies help us to provide you with an excellent service.

  DISDETTA LINEA TELEFONICA TELETU PDF

Where there are discrepancies between the Regulations and the standards referenced herein, the Regulations apply. The test data should describe the acceptance criteria and provide clinical justification for the criteria used.

Make sure your team reviews the product, considering its intended use, user, environment, and evaluations requirements. January Number of pages: The document is not intended to provide guidance for epicardial myocardial leads, temporary leads or external electrocardiography or defibrillator leads.

AFNOR Editions Online Store

Keeping them in mind from the beginning design phase and completing evaluations in a timely, cost-effective manner can help bring these devices to markets across the globe. The number of revolutions required to extend and retract a 14708–1 should be tested to ensure it meets the design specifications. A standard that specifies life cycle requirements for the development of medical 14078-1 and software used within medical devices, it includes provisions for risk management, maintenance, and configuration.

Legal notices Photo credits FAQ. The manufacturer should report lead handling characteristics, procedural success and user observations with regard to the implantation procedure in animals. It is possible that additional testing may be required based on the specific nature of the lead. Fatigue testing that approximates flexural stresses on 14708- segments at critical anatomic zones e.

1408-1 for surgery — Skeletal pins and wires — Part 2: Active implantable medical devices include technologies like pacemakers, defibrillators, infusion pumps, cochlear implants, and neurostimulators.

Active Implantable Medical Device Testing: What You Need To Know – Medical Product Outsourcing

Additionally, many new AIMD systems communicate wirelessly with the implant and other external equipment. It supplements other guidance documents on general application processes and procedures for Class IV and other medical devices. Provide supporting data indicating the maximum quantity of the active ingredient that could be provided with the lead. A link, button 147081 video is not working. A Environmetal and Sterilization Testing.